Health and Safety Code § 791.014: MINIMUM SPECIFICATIONS FOR INTERIOR FIRE ESCAPES
No bill in the 90th Legislature changes this section yet
Follow this section in Texas Bill Atlas: a bill filed later that changes it shows up as new.
Part of Health and Safety Code Chapter 791, with every bill that changes it.
Bills are matched to sections automatically from their text and can be missed, for example when a bill changes a whole chapter at once or renumbers sections. No bill listed here does not mean no bill changes this section.
Current law
Sec. 791.014. MINIMUM SPECIFICATIONS FOR INTERIOR FIRE ESCAPES. (a) An interior fire escape may be:
(1) a stairway composed of iron, steel, or concrete; or
(2) a straight or spiral chute composed of iron or steel.
(b) The fire escape must be enclosed with a noncombustible material. All door and window openings in the enclosure must be protected with self-closing fireproof shutters.
(c) Balconies or landings used with an interior fire escape must meet the construction requirements imposed under Section 791.012, except that a balcony used with an interior fire escape must permit at least 40 inches of unobstructed passageway, and the balconies or landings must be located on a level with the floors of the building.
(d) The stairs of an interior stairway fire escape must meet the requirements imposed under Section 791.012, except that the stairs must permit at least 40 inches of unobstructed passageway in all parts. An interior stairway fire escape may not use stairs of the types known as "spirals" or "winders".
(e) An interior stairway fire escape must be continuous, starting at the ground floor, and may not descend to any basement. It must extend through the roof of the building and must terminate in a penthouse constructed of noncombustible material equipped with a self-closing fire door as specified in this section.
(f) An interior chute fire escape must meet the requirements of Section 791.013.
(g) An interior fire escape must be accessible from all parts of the building it is designed to serve. Each lobby, hall, or passageway that leads to a fire escape and is used in connection with it must be at least 36 inches wide and at least six feet six inches high and must be level with the floor on which the fire escape opens and which it serves. The fire escape must be constructed at the lower end in a manner that permits direct exit to the outside of the building at the grade.
(h) The enclosing walls of an interior fire escape may be constructed of:
(1) brick;
(2) plain solid concrete;
(3) reinforced stone or gravel concrete;
(4) reinforced cinder concrete;
(5) hollow terra-cotta blocks;
(6) hollow concrete blocks composed of stone or cinder concrete mortar;
(7) gypsum blocks; or
(8) metal lath on steel studding.
(i) If the enclosing walls are of brick or plain solid concrete, they must be at least eight inches thick for the top 30 feet, increasing four inches in thickness for each lower section of 30 feet or fraction of 30 feet, or at least eight inches thick for the entire height if the walls are wholly supported at intervals not to exceed 30 feet. If the enclosing walls are of reinforced stone or gravel concrete, they must be at least five inches thick for the top 30 feet, increasing two inches in thickness for each lower section of 30 feet or fraction of 30 feet, or at least three inches thick for the entire height if supported at vertical intervals not to exceed 20 feet and if braced as necessary with lateral supports or suitabl
The section continues: whole chapter.